    Cooling Capacity (W) Dimensions (mm)
    Product Code SC2 = -8C SC1 = 0C Fans (No) Air Throw (m) Height Width Depth Price Qty
    EG-125AC4-C23-C24 1292 1930 1 4.9 245 900 685
    £999.99

    Out of stock

    EG-125AE4-C23-C18 1606 2351 1 4.2 245 900 685
    £279.06
    EG-225AC4-C23-C8 2816 4158 2 6.6 245 1500 685
    £999.99

    Out of stock

    EG-225AE4-C23-C12 3167 4643 2 5.6 245 1500 685
    £999.99

    Out of stock

    EG-130AE4-C25-C12 2442 3584 1 5.9 245 1100 685
    £350.35
    EG-130AE4-C21-C12 2754 4038 1 6.9 245 1100 685
    £384.57
    EG-325BE4-C23-C12 4847 7089 3 7.1 245 1380 685
    £999.99

    Out of stock

    EG-230BC4-C25-C10 4111 6083 2 9.1 370 1260 685
    £489.84
    EG-425BE4-C23-C10 6287 9218 4 8.3 370 1740 685
    £999.99

    Out of stock



    Karyer - Unit Cooler - Angled Ceiling Type


    Application


    The EG model unit coolers, having the range 1,00 – 17,00 kW, are able to satisfy small and medium cooling capacity needs for commercial type cold storage.

    The coils, in unit coolers, are quite compact in addition to their thermally high efficient performance.

    Additionally, we have the EG-G Angled Ceiling Type Glycol Cooler range for usage of water/glycol mixture to be used in cold rooms.


    Coil Properties


    Unit coolers are designed with optimum tube diameter in order to increase efficiency of unit coolers. Products can be provided with range of fin spacing as 4,20 , 7,00 mm. Maximum operation pressure is 25 barg.


    Casework


    It is manufactured with electrostatic Ral 9016 powder painted galvanized sheets to resist corrosion; it has attractive view in addition to its rigidity. Additionally, screwed side panels and hinged drain pan can be easily removed to facilitate installation and maintenance operations.


    Fan


    The unit coolers can be provided with monophase blowing Q motor and axial fans with Ø250 and Ø300mm diameters. Protection class of fans is IP41 for Q motors, IP44 for axial fans. Axial fans are compatible with ERP 2015 regulation.


    Electrical Heater


    High-quality electrical heaters are placed on the coil and drain pan according to working and design conditions.


    Options


      Unit coolers can be provided with below options;


    • Gold Epoxy Fins

    • Stainless Steel Case

    • EC Fan
















































    Karyer Part Number Lu-Ve Part Number
    EG-125AC4-C23-C24 FHA-30-E32
    EG-125AE4-C23-C18 FHA-40-E32
    EG-130AE4-C21-C12 FHA-53-E5
    EG-225AC4-C23-C8 FHA-60-E32
    EG-130AE4-C25-C12 FHA-41-E5
    EG-225AE4-C23-C12 FHA-80-E32
    EG-130AE7-C25-C12 FHA-35-E8
    EG-325BE4-C23-C12 FHA-100-32
    EG-230BC4-C25-C10 FHA-79-E5
    EG-425BE4-C23-C10 FHA-160-32


    Please contact us for option requests.





    Please Note: For all Export orders a member of our team will contact you to arrange shipping

    Please Note - In some cases the alternatives might be under or over powered or dimensionally different, if you are unsure we recommend calling the office on 01483 869100

    Why CO2?: Natural refrigerant

    EU F-Gas Regulation is a key priority for European countries. It ensures compliance with the Kigali Amendment supporting international climate commitments on greenhouse gases and leading the global transition to climate-friendly HFC-free technologies.

    Carbon dioxide (R–744) is regaining its place in the refrigeration world. Driven by environmental concerns, legislation is requiring increased adoption of ‘alternative’ refrigerants, of which CO2 is one.

    CO2 is a very attractive refrigerant from an environmental perspective. Zero ODP and “GWP” (Global Warming Potential)=1 means natural substance in the atmosphere.

    In Europe a step-by-step HFC reduction has been in place since the F Gas regulation was introduced in 2015. In fact, not only in Europe but also other countries all over the world have actively been preparing to enact the necessary domestic legislation to implement the agreement for reducing the use of HFCs.

    Panasonic is now able to provide a solution in Europe with CO2 refrigeration systems to prevent global warming and to support environment-friendly retail operations.

    The following table shows how well R744 (CO2) performs regarding environmental impact and safety.

    Karyer - Unit Cooler - Angled Ceiling Type


    Application


    The EG model unit coolers, having the range 1,00 – 17,00 kW, are able to satisfy small and medium cooling capacity needs for commercial type cold storage.

    The coils, in unit coolers, are quite compact in addition to their thermally high efficient performance.

    Additionally, we have the EG-G Angled Ceiling Type Glycol Cooler range for usage of water/glycol mixture to be used in cold rooms.


    Coil Properties


    Unit coolers are designed with optimum tube diameter in order to increase efficiency of unit coolers. Products can be provided with range of fin spacing as 4,20 , 7,00 mm. Maximum operation pressure is 25 barg.


    Casework


    It is manufactured with electrostatic Ral 9016 powder painted galvanized sheets to resist corrosion; it has attractive view in addition to its rigidity. Additionally, screwed side panels and hinged drain pan can be easily removed to facilitate installation and maintenance operations.


    Fan


    The unit coolers can be provided with monophase blowing Q motor and axial fans with Ø250 and Ø300mm diameters. Protection class of fans is IP41 for Q motors, IP44 for axial fans. Axial fans are compatible with ERP 2015 regulation.


    Electrical Heater


    High-quality electrical heaters are placed on the coil and drain pan according to working and design conditions.


    Options


      Unit coolers can be provided with below options;


    • Gold Epoxy Fins

    • Stainless Steel Case

    • EC Fan
















































    Karyer Part Number Lu-Ve Part Number
    EG-125AC4-C23-C24 FHA-30-E32
    EG-125AE4-C23-C18 FHA-40-E32
    EG-130AE4-C21-C12 FHA-53-E5
    EG-225AC4-C23-C8 FHA-60-E32
    EG-130AE4-C25-C12 FHA-41-E5
    EG-225AE4-C23-C12 FHA-80-E32
    EG-130AE7-C25-C12 FHA-35-E8
    EG-325BE4-C23-C12 FHA-100-32
    EG-230BC4-C25-C10 FHA-79-E5
    EG-425BE4-C23-C10 FHA-160-32


    Please contact us for option requests.





    Please Note: For all Export orders a member of our team will contact you to arrange shipping

    Delivery & Returns

    Delivery Policy

    For Quick Pick and website items only, delivery is free of charge for orders over £50.00. For Quick Pick and website orders below £50.00, a £15.00 delivery and administration fee will be charged.

    Hawco offers a next day delivery service for orders placed before 4pm Monday - Friday. The delivery service is standard to all central UK. If you require overseas or timed delivery, please call the sales office on Hawco: 01483 869070

    Special Carriage Costs

    When ordering online and chosing a "Special Carriage Charge" the times given are subject to a 30 minute grace period (therefore 10:30 deliveries have up to 11am to be delivered) and work off a next working day basis. Please make sure that if a timed carriage option is selected that someone is available to sign for the consignment as without this it will be subject to being returned to the delivery depot for a redelivery 1-2 days later.

    N.B - Deliveries requested for Pre 9.30am are subject to being delivered as early at 7am.

    N.B - All orders processed after 4pm, weekends or Bank Holidays are subjected to being processed the following working day

    Returns Policy

    An RMA request must be completed online at http://hawco.returnsportal.net/

    If approved, an automated RMA email will be sent. This will reference a unique RMA number. The automated RMA approval email will prompt you to log into the online returns system and print off the RMA packing slip, which is to be affixed to the outside of the packaging.

    N.B. Returns will not be accepted without a returns authorisation number (RMA) and will be returned at the sender’s expense.

    When you have your returns authorisation number (RMA), please ensure you send the return to our Logistics Centre:

    Hawco Logistics Centre,
    8 Cranfield Road,
    Lostock Industrial Estate,
    Lostock,
    Bolton, UK
    BL6 4SB

    N.B. - Any returns sent to the Hawco Head Office in Godalming and not the Logistics Centre address in Bolton will be refused. This may cause excessive delay in handling the return, or possible loss if your carrier mislays the delivery. Hawco cannot accept any liability for items which are not correctly addressed or packaged for return.

    Credit or replacement product will only be issued on receipt and Hawco’s acceptance of faulty or damaged items. Items that are returned which are subsequently determined to have been damaged by the customer and or by their agent may be subject to an investigation and admin fee. In all instances any logistical costs incurred by Hawco during this process will be chargeable.

    Item(s) must be returned within 7 days of the issue of the returns number. If not returned by this date then no credit will be given.

    Items ordered incorrectly or that are surplus to requirements may be subject to a 20% restocking charge and will only be accepted within the first 3 months of sale and are still in the original packaging. Items ordered in specifically may be refused entirely.

    N.B. No credit will be issued to any surplus items that are received damaged.

    The customer has a 3 day window to report items that have been received damaged, failure to do so will result in your returns claim being rejected.

    All deliveries and returns are subject to our standard Terms & Conditions of sale. - See more at: http://hawco.returnsportal.net/ReturnPolicy/

    Please Note - In some cases the alternatives might be under or over powered or dimensionally different, if you are unsure we recommend calling the office on 01483 869100